U-Type Conductor bar
General
KU12 conductor bar system is designed in accordance with today's international safety requirements.
Any number of conductor bars can be installed side-by-side next to each other with minimum space requirements, occupying a small space.
It is widely used in automatic storage systems, monorail automated trolleys, inspection/production lines, and playground facilities, as well as for data and communication transmission.
Product Description
KU12 Conductor Bar
The insulation housing is made of high-quality PVC, which provides optimum insulation and safety protection.
Standard sizes are 4 m / 6 m each, other sizes are available on request.
The minimum installation distance is 14 mm and the minimum radius of the arc section is 400 mm.
Model |
Conductor material |
Cross section area (mm²) |
Leakage distance of covers (mm) |
Max. voltage (V) |
Continuous ampere capacity (A) |
Resistance (Ohm/km) |
No. |
KU12C |
copper |
25 |
30 |
660 |
100 |
0.745 |
201021001 |
KU12F |
galvanized steel |
25 |
30 |
660 |
40 |
5.415 |
201021003 |
KU12E |
stainless steel |
25 |
30 |
660 |
10 |
31.56 |
201021004 |
*The KU12C is used for power supply, control and data transmission; the KU12F is used for non-corrosive environments; the U12E is used for data transmission in corrosive environments.
Parameters of the PVC insulation housing
Item |
Standard (green) |
High temp. |
Electrical properties |
30-40kv/mm |
45kv/mm |
Specific resistance |
5× 1015 Ohm×cm |
5× 1017 Ohm×cm |
Surface resistance |
1013 Ohm |
1015 Ohm |
Leakage resistance |
CTI600-1.1 |
CTI600-1.1 |
Mechanical properties Flexible strength |
75N/mm²± 10% |
95N/mm²± 10% |
Tensile strength |
50N/mm²± 10% |
50N/mm²± 10% |
Temperature |
-30℃ to 55℃ |
-30℃ to 110℃ |
Flame test |
Class B1,no flaming particles, self-extinguished |
|
No. |
201021005 |
201021006 |
For accessories, please download catalogue to get more details.